- Description
- Ask a Question
- Reviews
VACUUM MATTRESS | FOR INJURED IMMOBILIZATION
• Vacuum mattress for patient immobilization.
• Its dimensions fit LECCO, 911, Rolly and Kit Everest stretchers, keeping the patient immobilized even while in a vertical position.
• There is no interference with X-rays nor MRI.
• The operating temperature ranges from +60 °C to -20 °C.
• A maximum load of 150 kg is recommended.
• The mattress is made with a double layer of PVC, guaranteeing maximum resistance to penetration, abrasion and tears, more durability and it's easy to repair.
• The external PVC is tested according to UNI4818-16 for solvent resistance and according to EN-ISO811 for waterproofing.
• It is also tested for flame retardancy according to UNI 9177 Class 2.
• The mattress can be better adapted to the patient's head due to shaping which is hollowed specifically for that purpose.
• Vacuum valve is on the side for optimal use.
• The loops for attaching straps and handles are equipped with extra support tape to guarantee greater durability.
• The carry handles join together under the structure, guaranteeing greater resistance since they do not weigh directly on the loops.
• Each product is tested for 24 hours under vacuum before leaving the factory.
• The carry bag is made of Cordura® 1000 Denier Nylon with a 10 mm zipper.
• The mattress handles and straps are made of 40 mm polypropylene webbing.
• Aluminum vacuum pump and carry bag included.
• Completely made in Italy.
• Included accessory: KIT VACUUM EVEREST (#855150000KK) for connecting the Vacuum to the Everest rescue bag.
Specifications:
• Ref.: 872.07
• DM: Classe I
• UDI-DI: 08023577068695
• Standards: EU REGULATION 2017/745
• Material: PVC
• Weight: 4,9kg
• Length (cm): 181
• Width (cm): 70
• Color: Orange/Black
Specifications
Part Number: 872070000KK Weight: 11.9 lbs.
- Description
- Ask a Question
- Reviews
VACUUM MATTRESS | FOR INJURED IMMOBILIZATION
• Vacuum mattress for patient immobilization.
• Its dimensions fit LECCO, 911, Rolly and Kit Everest stretchers, keeping the patient immobilized even while in a vertical position.
• There is no interference with X-rays nor MRI.
• The operating temperature ranges from +60 °C to -20 °C.
• A maximum load of 150 kg is recommended.
• The mattress is made with a double layer of PVC, guaranteeing maximum resistance to penetration, abrasion and tears, more durability and it's easy to repair.
• The external PVC is tested according to UNI4818-16 for solvent resistance and according to EN-ISO811 for waterproofing.
• It is also tested for flame retardancy according to UNI 9177 Class 2.
• The mattress can be better adapted to the patient's head due to shaping which is hollowed specifically for that purpose.
• Vacuum valve is on the side for optimal use.
• The loops for attaching straps and handles are equipped with extra support tape to guarantee greater durability.
• The carry handles join together under the structure, guaranteeing greater resistance since they do not weigh directly on the loops.
• Each product is tested for 24 hours under vacuum before leaving the factory.
• The carry bag is made of Cordura® 1000 Denier Nylon with a 10 mm zipper.
• The mattress handles and straps are made of 40 mm polypropylene webbing.
• Aluminum vacuum pump and carry bag included.
• Completely made in Italy.
• Included accessory: KIT VACUUM EVEREST (#855150000KK) for connecting the Vacuum to the Everest rescue bag.
Specifications:
• Ref.: 872.07
• DM: Classe I
• UDI-DI: 08023577068695
• Standards: EU REGULATION 2017/745
• Material: PVC
• Weight: 4,9kg
• Length (cm): 181
• Width (cm): 70
• Color: Orange/Black